industrial-engineering-systems

Industrial engineering systems are a set of technical systems designed to ensure normal operation and production processes at industrial enterprises. These systems include various engineering communications, equipment and devices necessary to ensure efficient and safe operation of the enterprise.

composition of engineering systems of industrial buildings

Industrial ventilation

Industrial ventilation is needed to remove pollutants that enter the air during production, protect personnel from negative factors.

Engineering networks for the supply of clean and removal of polluted air are designed taking into account the volume of the workshop and sanitary standards. To increase the energy efficiency of the building, the air masses are heated using heat exchangers or heat exchangers. Devices for humidification or dehumidification, dust filtration can also be installed in workshops.

OFFERED RANGE

FANS

  • DUCTED AIR BACK-UP FAN

  • ROOF RADIAL FAN SERIES VKH-C

  • AXIAL FAN IN A SOUNDPROOF HOUSING OF THE SERIES AHD

  • AXIAL SMOKE EXTRACTION FAN OF THE AIR AKD SERIES

  • EXPLOSION-PROOF AXIAL FAN OF THE AIR HCT SERIES

MODULAR INSTALLATIONS (ACS Klima)

  • General industrial purpose

    ACS Klima modular installations can be used in public, administrative and industrial buildings for various purposes due to the variability of configurations and materials used.

  • Exterior design / roof tops

    Installations of this design are designed to be placed outdoors, on specially prepared sites or on the roof of a building.

  • For a cold climate

    The units in this version are designed for operation in temperate and cold climates at air temperatures up to -50 °C.

  • For swimming pools

    The units of this design are designed to provide heating, dehumidification and ventilation of the pool with minimal energy consumption.

  • Hygienic design

    Installations of this design are designed for healthcare facilities, pharmaceutical and chemical industries.


Industrial air conditioning

Centralized cooling systems are used to reduce the air temperature in the workshop to a comfortable level. They are designed taking into account heat generation, climate, air humidity, and the required frequency of air exchange.
The climate control equipment can be equipped with additional modules. They ionize the air in the room, purify it from microorganisms. For some industries (radio electronics, chemistry), precision air conditioning systems are needed, which very precisely maintain the microclimate in isolated rooms.

OFFERED RANGE

AIR-COOLED CHILLERS of the HNG series (112-600 kW)

This series of air-cooled chillers has high efficiency, compact dimensions and low noise. The TRTP series chillers are designed for cooling water or water glycol mixtures in commercial and industrial premises, and are also widely used for cooling process equipment. The HNG range is represented by 15 models with cold capacity: from 112 to 600 kW, calculated at an outdoor temperature of +35°C.

Brief characteristics

  • Cold capacity range: 112-600 kW
  • Operating mode: heat/cold
  • Compressor type: spiral
  • Fan type: axial
  • Evaporator type: plate type
  • Capacitor type: Microchannell

Standard equipment

The HG series chillers are equipped as standard with a spiral compressor with asymmetric performance control, axial fans, a stainless steel plate type evaporator, microchannel capacitors and an integrated automation system. Due to the possibility of using a modular design, the system's performance can be increased to 1126 kW.

The range of models of HNG series chillers

  • HNG 46

    Air-cooled chiller

    Cooling: 230,3 kW
    Нагрев: 237,2 kW

     

  • HNG 56

    Air-cooled chiller

    Cooling: 142,0 kW
    Нагрев: 146,0 kW

     

  • HNG 78

    Air-cooled chiller

    Cooling: 199,7 kW
    Нагрев: 205,6 kW

     

  • HNG 90

    Air-cooled chiller

    Cooling: 230,3 kW
    Нагрев: 237,2 kW

     

  • HNG 120

    Air-cooled chiller

    Cooling: 348,6 kW
    Нагрев: 358,2 kW

     

  • HNG 155

    Air-cooled chiller

    Cooling: 399,8 kW
    Нагрев:  411,1 kW

     

  • HNG 180

    Air-cooled chiller

    Cooling: 478,1 kW
    Нагрев:   491,9 kW

     

COMPRESSOR AND CONDENSER UNITS

This series of compressor and condenser units has high efficiency, compact dimensions and low noise level. Compressor and condenser units are designed to remove heat and supply refrigerant to consumers in commercial and industrial air conditioning systems, and are also widely used in ventilation systems. The MNG series KKB line is represented by 35 standard standard sizes with cold capacity: from 10 to 600 kW.

Brief characteristics

  • Cold capacity range: 10-600 kW
  • Operating mode: heat/cold
  • Compressor type: spiral
  • Fan type: axial
  • Capacitor type: Microchannel
  • Refrigerant: R410A, R407C

Standard equipment

Compressor and condenser units are equipped as standard with a spiral compressor with asymmetric performance control, axial fans, microchannel capacitors with an increased heat exchange surface and an integrated automation system. As standard, compressor and condenser units are designed to operate at outdoor air temperatures from -0°C to +45°C in cooling mode.

The range of models of compressor and condenser units of the MNG series

  • MNG 10

    Water-cooled chiller

    Cooling: 10,2 kW

     

  • MNG 20

    Water-cooled chiller

    Cooling: 20,2 kW

     

  • MNG 30

    Water-cooled chiller

    Cooling: 27,2 kW

     

  • MNG 45

    Water-cooled chiller

    Cooling: 43,1 kW

     

  • MNG 56

    Water-cooled chiller

    Cooling:  55,9 kW

     

  • MNG 90

    Water-cooled chiller

    Cooling:  88,9 kW

     

  • MNG 115

    Water-cooled chiller

    Cooling:  118,3 kW

     

  • MNG 130

    Water-cooled chiller

    Cooling:  130,6 kW

     

  • MNG 190

    Water-cooled chiller

    Cooling:  185,1 kW

     


Industrial heating

The air or water heating system creates comfortable working conditions in industrial premises.

Heating systems in industrial premises are built taking into account such rules:

  • They must warm up the air to the desired temperature according to the requirements of labor protection;
  • The intensity of the heaters is selected depending on the amount of thermal energy that is released by the production machines;
  • It is not allowed to pollute the air with smoke, gorenje products, if solid or liquid fuel boilers, furnaces are used for heating;
  • The heating system is usually integrated with ventilation, air conditioning to maintain a microclimate depending on external conditions;
  • When designing an engineering network, the requirements of fire safety and explosion safety of the facility are taken into account;
  • The system should be cheap and convenient during operation, easy to maintain.

Send a request

We will take into account the delivery time.
We will form a commercial offer
that is profitable for you!

Invalid Input